Users Guide

Table Of Contents
Software Version : 10.5.0.0
Physical Ports : 48x10GbE, 2x40GbE, 4x100GbE
BIOS : 3.33.0.0-3
System CPLD : 0.4
Master CPLD : 0.10
Slave CPLD : 0.7
-- Power Supplies --
PSU-ID Status Type AirFlow Fan Speed(rpm) Status
----------------------------------------------------------------
1 up AC NORMAL 1 13312 up
2 fail
-- Fan Status --
FanTray Status AirFlow Fan Speed(rpm) Status
----------------------------------------------------------------
1 up NORMAL 1 13195 up
2 up NORMAL 1 13151 up
3 up NORMAL 1 13239 up
4 up NORMAL 1 13239 up
Diagnostic commands
location-led interface
Changes the location LED of the interface.
Syntax
location-led interface ethernet {chassis/slot/port[:subport]} {on | off}
Parameters
chassis/slot/port[:subport] — Enter the ethernet interface number.
on | off — Set the interface LED to be on or off.
Default Not configured
Command Mode EXEC
Usage Information Use this command to change the location LED for the specified interface.
Example
OS10# location-led interface ethernet 1/1/1 on
OS10# location-led interface ethernet 1/1/1 off
Supported
Releases
10.3.0E or later
location-led system
Changes the location LED of the system.
Syntax
location-led system {node-id | node-id/unit-id} {on | off}
Parameters
node-id | node-id/unit-id — Enter the system ID.
on | off — Set the system LED to be on or off.
Default Not configured
Command Mode EXEC
Usage Information Use this command to change the location LED for the specified system ID.
Example
OS10# location-led system 1 on
OS10# location-led system 1 off
1286 Troubleshoot OS10