Users Guide

Table Of Contents
MASTER-IPV4 : 100.69.101.170
PREFERRED-MASTER :
------------------------------------
----------------------
MX9116N-A1#
Sample output from a Chassis-group Master:
MX9116N-A2# show smartfabric cluster
------------------------------------
----------------------
CLUSTER DOMAIN ID : 159
VIP :
fde1:53ba:e9a0:de14:0:5eff:fe00:1159
ROLE : MASTER
SERVICE-TAG : MXWV122
MASTER-IPV4 : 100.69.101.170
PREFERRED-MASTER :
------------------------------------
----------------------
MX9116N-A2#
ii. On the networking switch with the ROLE as
MASTER, run the "show smartfabric cluster member"
command to get the details of all the discovered
switches in the OME Modular Chassis group. This
command output provides a reference for the
upgrade procedure.
MX9116N-A2# show smartfabric
cluster member
Service-tag IP
Address
Status Role Type
Chassis-Service-Tag Chassis-Slot
------------------------------------
------------------------------------
------------------------------------
--------------
MXWV122
fde1:53ba:e9a0:de14:2204:fff:fe20:56
c9 ONLINE MASTER MX9116n
SKYMX02 A2
MXLE103
fde1:53ba:e9a0:de14:2204:fff:fe21:ca
c9 ONLINE BACKUP MX9116n
SKYMX10 B2
MXLE093
fde1:53ba:e9a0:de14:2204:fff:fe21:7f
c9 ONLINE BACKUP MX9116n
SKYMX10 B1
MXWV011
fde1:53ba:e9a0:de14:2204:fff:fe21:9f
49 ONLINE BACKUP MX9116n
SKYMX02 A1
MX9116N-A2#
iii. It is highly recommended to upgrade all the
networking switches (MX9116n and MX5108n) in
the MSM Chassis group to 10.5.0.5. During the
upgrade process, it is not recommended to make any
configuration changes in the chassis-group.
iv. For upgrading the networking switch from 10.4.0E
(R3S or R4S), refer to the Upgrade and Downgrade
Getting Started with Dell EMC SmartFabric OS10
69