Table 155. PartitionInfo (continued)
Name Description Schema
WWNode
optional
WWN of Partition string
Micw
optional
Multi-initiator conflict warning
enabled
enum (TRUE, FALSE)
Slot
Partition data.
Table 156. Slot
Name Description Schema
PhysicalNumber
required
The physical slot number starting
at 0. The slot number 0 is always
the bottom slot in the left
magazine of a 7 module stack. In
a single base library, the physical
slot number always starts at 120.
Formula is ModuleNo*40+
(SlotNumber in Module).
integer
LogicalNumber
optional
The logical slot number includes
the module number as prex and
starts always at 1 in a module.
Format - ModuleNo.(SlotNumber
in Module).
string
Module
optional
The Expansion Module where the
slot is located.
integer
Partition
optional
The partition (logical library)
where the slot is assigned to. If
no partition is assigned, the value
is 0.
integer
Mailslot
optional
If the slot is mapped as a
mailslot (I/O Station), this entry
is set to TRUE.
enum (TRUE, FALSE)
Cartridge
optional
If a cartridge is detected in the
slot, this entry is set to TRUE.
enum (TRUE, FALSE)
CartridgeType
optional
Type of Cartridge: Data, Cleaning,
WORM, etc.
enum (Unknown, Data, Cleaning,
Worm, N/A)
CartridgeSubType
optional
SubType of a Cartridge
0=Default, 1=Type M
integer
CartridgeGeneration
optional
Generation of the cartridge integer