Users Guide

Setting up the Embedded Box PC
WARNING: During the installation of the Embedded Box PC, the responsible party or integrator must use the power
adapter provided with the Embedded Box PC, or connect to a 12-26 VDC separate power source already present as part
of the clients installation. Always ensure that the available power source matches the required input power of the
Embedded Box PC. Check the input power markings next to power connector(s) before making connections.
WARNING: Before you begin any of the procedures in this section, read the safety information that shipped with your
Embedded Box PC. For additional best practices information, go to www.dell.com/regulatory_compliance.
NOTE: To ensure that the protection provided by the Embedded Box PC is not impaired, do not use or install the
Embedded Box PC in any manner other than what is specified in this manual.
NOTE: To provide additional power connections to the main network, use cables appropriate for the load currents such
as, 3-core cable rated 15 A at 90°C (194°F) minimum, which conform to either IEC 60227 or IEC 60245. The Embedded
Box PC accepts cables from 0.8 mm to 2.5 mm (18 AWG to 14 AWG).
WARNING: The symbol indicates hot surface or adjacent hot surface that can obtain temperature during normal
use that can cause a burn. Allow equipment to cool off or use protective gloves when handling to reduce risk of a burn.
WARNING: This product is designed for specific applications and must be installed by qualified personnel with RF and
regulatory related knowledge. The general user must not attempt to install or change the setting.
WARNING: Before installation, the two power inputs (Terminal Block or Power Jack) must be protected by 20 A fuses or
circuit-breakers, which are over current protection devices in front of the Embedded Box PC.
WARNING: The product shall be installed at a location where the radiating antenna is kept 20 cm away from nearby
persons in its normal operating condition to meet regulatory RF exposure requirements.
WARNING: Use only the antenna(s), which are approved by Dell.
NOTE: Connect a certified SELV power to either Phoenix connector or the Barrel connector only. The connection of two
power sources may damage equipment and present risk of fire.
WARNING: If your equipment or accessories are provided with a detachable main supply cord set and has to be replaced,
ensure that the replacement cord set has an adequate voltage, current, and temperature rating for the country where
the equipment is installed. The cord set must comply to the local safety code, regulations, and law.
Professional installation instructions
Installation personnel
This product is designed for specific applications and needs to be installed by qualified personnel with RF and regulatory related
knowledge. The general user shall not attempt to install or change the setting.
Installation location
The product shall be installed at a location where the radiating antenna is kept 20 cm from nearby persons in its normal operation condition
in order to meet regulatory RF exposure requirements.
External antenna
Use only the antenna(s) which have been approved by the applicant. Non-approved antenna(s) may produce unwanted spurious or
excessive RF transmitting power which may lead to a violation of FCC/IC limits and is prohibited.
Components
Frequency (MHz) Antenna Type Brand
Gain (dBi)
Main Aux
WLAN 2412~2462 Dipole Laird 2.9 2.9
3
Setting up the Embedded Box PC 13