Users Guide
Maximum shock
5000 5100
Operational 40 G, 2 ms 40 G, 2 ms
Non-operational 160 g, 2 ms Half Sine Shock 160 g, 2 ms Half Sine Shock
Maximum altitude
5000 5100
Operational
-15.2 m to 5000 m (-50 ft to 16,404 ft) -15.2 m to 5000 m (-50 ft to 16,404 ft)
Non-operational
-15.2 m to 10,668 m (-50 ft to 35,000 ft) -15.2 m to 10,668 m (-50 ft to 35,000 ft)
Power
Power adapter (optional)
General parameters
Power supply EPS Level V
Wattage 65 W
AC input voltage range 90-264 Vac
AC input current (low AC range/high AC range) 1.7 A/1.0 A
AC input frequency 47 Hz/63 Hz
Average eciency (ESTAR 5.2 compliant) 87%
DC parameters
+19.5 v output 19.50 V/ 3.34 A
Total power (maximum) 65 W
BTUs/h (based on PSU max wattage) 222 BTU
Power-input tolerances
24V AC/DC +10% to -25% (26.4 V to 18.0 V)
Power module—Battery connector
• Charging—Charging shuts down when the battery voltage
reaches 14 V.
• Powering the system—System will shutdown is the voltage
from the battery is below 10 V.
GPIOs voltage levels
GPIO voltage levels
GPIO 2~9 Bi-directional I/O, Analog input