Maximum shock
5000 5100
Operational 40 G, 2 ms 40 G, 2 ms
Non-operational 160 g, 2 ms Half Sine Shock 160 g, 2 ms Half Sine Shock
Maximum altitude
5000 5100
Operational
-15.2 m to 5000 m (-50 ft to 16,404 ft) -15.2 m to 5000 m (-50 ft to 16,404 ft)
Non-operational
-15.2 m to 10,668 m (-50 ft to 35,000 ft) -15.2 m to 10,668 m (-50 ft to 35,000 ft)
Power
Power adapter (optional)
General parameters
Power supply EPS Level V
Wattage 65 W
AC input voltage range 90-264 Vac
AC input current (low AC range/high AC range) 1.7 A/1.0 A
AC input frequency 47 Hz/63 Hz
Average eciency (ESTAR 5.2 compliant) 87%
DC parameters
+19.5 v output 19.50 V/ 3.34 A
Total power (maximum) 65 W
BTUs/h (based on PSU max wattage) 222 BTU
Power-input tolerances
24V AC/DC +10% to -25% (26.4 V to 18.0 V)
Power module—Battery connector
Charging—Charging shuts down when the battery voltage
reaches 14 V.
Powering the system—System will shutdown is the voltage
from the battery is below 10 V.
GPIOs voltage levels
GPIO voltage levels
GPIO 2~9 Bi-directional I/O, Analog input
75