Users Guide
Mechanical and environmental specications
Mounting bracket Swivel type (plastic)
Mounting bracket length (approximate) 175 mm (6.89 in)
Mounting bracket color Black
Pig tail length 1000 mm (39.37 in)
Coaxial cable specication
Impedance 50 ± 2.0 ohms
Structural return loss -16 dB or better from 100-2500 MHZ un-terminated sample (direct bridge
method)
Nominal RTL reference -16 dB or better to 6.0 GHz
Dielectric Foam FEP
Dielectric (outer diameter) 2.79 mm ± 0.076 mm (0.110 in ± 0.003 in)
Velocity of propagation 80%
Center conductor Solid copper, 0.94 mm ± 0.025 mm (0.037 in ± 0.001 in)
Shield #1 Foil, aluminium/poly tape, adhered to dielectric
Diameter over foil 3.02 mm ± 0.07 mm (0.119 in ± 0.003 in)
Shield #2 Braid, 90% 36-AWG tin/copper
Outer jacket Plenum PVDF, o-white, lead-free, and UV stable
Outer diameter 4.52 mm ± 0.15 mm (0.178 in ± 0.006 in)
Outer Jacket Plenum PVDF, O-white, lead free, and UV stable
Outer Diameter 4.52 mm ± 0.15 mm (0.178 in ± 0.006 in)
PLENUM rating CMP(ETL)C(ETL)
Attenuation dB/100 feet (nominal reference values)
• 8.0 dB@ 450 MHz
• 12.5 dB @900 MHz
• 19.6 dB@ l.8 GHz
• 23.6 dB @ 2.5 GHz
• 23.0 dB @ 3.0 GHz
• 27.5 dB @ 4.0 GHz
• 31.0 dB @ 5.0 GHz
• 35.0 dB @ 6.0 GHz
Installation temperature -20°C (-4°F) to +65°C (149°F)
Operating temperature -30°C (-22°F) to +65°C (149°F)
CC pullout 6 pound-force minimum, 16 pound-force maximum
Jacket pullout 4.5 pound-force minimum on 76.2 mm (3 in) section at 12.7 mm (0.5 in)
per minute
Minimum bend radius 12.7 mm (0.5 in) static bend
Leakage -90 dB
66