Specifications

Tested on all six sides; 160 G ± 5% with pulse duration of 2 msec ± 10% (equivalent to 50 in/sec [127
cm/sec])
Maximum altitude
Operational (maximum,
unpressurized)
–15.20 m to 5,000 m (–50 ft to 16,404 ft)
NOTE: The maximum temperature is derated 1°C/305 m (1000 ft) above sea level altitude.
Non-operational (maximum,
unpressurized)
–15.20 m to 10,668 m (–50 ft to 35,000 ft)
Operating environment
Temperature range (system)
Operating:
With 0.7 m/s airflow: –30°C to 75°C (–22°F to 167°F)
Without airflow: –30°C to 70°C (–22°F to 158°F)
Non-operating–With a maximum temperature gradation of 15°C (59°F) per hour:
With 0.7 m/s airflow: –40°C to 85°C (–40°F to 185°F)
Without airflow: –40°C to 85°C (–40°F to 185°F)
WARNING: The maximum operating temperature of the Edge Gateway is 70C (158°F). Do not
exceed this maximum temperature while operating the Edge Gateway inside an enclosure.
Internal heating of the Edge Gateway electronics, other electronics, and the lack of ventilation
inside an enclosure can cause the operating temperature of the Edge Gateway to be greater
than the outside ambient temperature. Continuous operation of the Edge Gateway at
temperatures greater than 70C (158°F) may result in an increased failure rate and a reduction
of the product life. Ensure that the maximum operating temperature of the Edge Gateway when
placed inside an enclosure is 70C (158°F) or less.
Temperature range (with
components)
Operating (SD card): –40°C to 85°C (–40°F to 185°F)
Operating (eMMC): –40°C to 85°C (–40°F to 185°F)
Maximum relative humidity
(non-condensing)
Operating: 10% to 90%–With a maximum temperature gradation of 15°C (59°F) per hour
Non-operating: 5% to 95%–With a maximum temperature gradation of 20°C (68°F) per hour
Pollution degree 2
NOTE: The ambient temperature is based on the free-air environment, system mounting, and certain workload assumptions.
NOTE: An open space of 63.50 mm (2.50 in) is recommended around the Edge Gateway for optimal air circulation.
NOTE: The maximum operating temperature may vary, depending on factors such as air flow, system mounting, software
applications, and so on.
NOTE: The temperature at the center of the exposed base surface must not exceed 82°C (179.6°F).
NOTE: For optimal thermal distribution when mounted, ensure that Edge Gateway is installed as instructed in the supplied
documentation.