Specifications
2
Environmental and operating conditions
Environmental conditions
Table 5. Environmental conditions
Ingress protection rating IP50
Water and dust ingress IEC 60529
CAUTION: Install the Edge Gateway in an area that is not exposed to direct sunlight.
NOTE: The Edge Gateway underwent and complies with salt fog testing conducted according to Mil-Std-810G Method 509.5,
Procedure 1.
NOTE: For outdoors and rugged environments, install the Edge Gateway in an external enclosure (sold separately).
Operating conditions
Table 6. Operating conditions
Maximum vibration
Operational
• 5 Hz with 0.0002 G
2
/Hz
• 350 Hz with 0.0002 G
2
/Hz
NOTE: Operational values are based on the 0.26 Grms profile. These values are tested for all
operational orientations and are retrieved from two minutes per test orientation with IO meter.
NOTE: All screws on the Edge Gateway are embedded with a Nylock seal to resist vibration and
loosening.
Non-operational
• 10 Hz with 0.003 G
2
/Hz
• 20 Hz with 0.01 G
2
/Hz
• 250 Hz with 0.01 G
2
/Hz
NOTE: Non-operational values are based on the 1.54 Grms profile. These values are tested for
all non-operational orientations and are retrieved every sixty minutes per test orientation with
IO meter.
Long Life Vibration 0.79 Grms
NOTE: The values are tested for all operational orientations and are retrieved every five hours
per test orientation with IO meter.
Maximum shock
Operational
Half sine shock
All operational orientations; 40 G ± 5% with pulse duration of 2 msec ± 10% (equivalent to 20 in/sec
[51 cm/sec])
Non-operational
Half sine shock
7