Owners Manual

Temperature specications
Table 11. Temperature specications
Temperature Specications
Storage –40°C to 65°C (40°F to 149°F)
Continuous operation (altitudes under 950 m / 3,117 ft) 10°C to 35°C (50°F to 95°F), avoiding direct sunlight
Fresh air For information about fresh air, see Expanded Operating Temperature section.
Maximum temperature gradient (operation and storage) 20°C/h (36°F/h)
Relative humidity specications
Table 12. Relative humidity specications
Relative humidity Specications
Storage 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be
non-condensing at all times.
Operating 10% to 80% relative humidity with 29°C (84.2°)
Maximum vibration specications
Table 13. Maximum vibration
specications
Maximum vibration Specications
Operating 0.26 Grms at 5 Hz to 350 Hz (all operational orientations)
Storage 1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested)
Maximum shock specications
Table 14. Maximum shock
specications
Maximum shock Specications
Operating 24 executed shock pulses 6 G in the positive and negative x, y, z axis up to 11
ms (four pulses on each side of the system)
Storage Six consecutively executed shock pulses of 71 G in the positive and negative
x, y, z axes up to 2 ms (one pulse on each side of the system)
16 Technical specications