Owners Manual

120
Drives
Dual-node systems with two server sleds Up to 90 3.5-inch hot-swappable Serial Attached
SCSI (SAS) HDDs, SATA HDDs, or SATA SSDs, or
Up to 12 hot-swappable SAS SSDs
Up to four 2.5-inch hot-swappable boot SATA SSDs
Connectors (per server sled)
Back
NIC Four 10/100/1000 Mbps
Serial 9-pin, DTE, 16550-compatible
USB One 9-pin, USB 3.0-compliant
One 4-pin, USB 2.0-compliant
Video 15-pin VGA
Internal
USB One 9-pin, USB 3.0-compliant
Video
Video type Integrated Matrox G200
Video memory 16 MB shared
Environmental specifications
NOTE: For additional information about environmental measurements for specific system
configurations, see dell.com/environmental_datasheets.
Temperature
Storage –40°C to 65°C (–40°F to 149°F)
Continuous operation (for altitude less than
950 m or 3117 ft)
10°C to 35°C (50°F to 95°F) with no direct sunlight
on the equipment.
Fresh air For information about fresh air, see Expanded
Operating Temperature section.
Maximum temperature gradient (operating and
storage)
20°C/h (36°F/h)
Relative humidity
Storage 5 to 95 percent RH with 33°C (91°F) maximum dew
point. Atmosphere must be non-condensing at all
times.