Cooling shroud
The cooling shroud aerodynamically directs the airflow across the entire system. The airflow passes through all the critical parts
of the system, where the vacuum pulls air across the entire surface area of the heat sink, thus allowing increased cooling.
Removing the cooling shroud
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by
your warranty. Read and follow the safety instructions that are shipped with your product.
1. Follow the safety guidelines listed in the Safety instructions section.
2. Follow the procedure listed in the Before working inside your system section.
3. If connected, disconnect the cables from expansion card(s).
NOTE: If required, close the expansion card latch on the cooling shroud to release the full length card.
4. If installed, remove the expansion card riser.
CAUTION: Never operate your system with the air shroud removed. The system may get overheated quickly,
resulting in shutdown of the system and loss of data.
Steps
Hold the sides of the cooling shroud and lift the cooling shroud away from the system.
Figure 13. Removing the cooling shroud (135 W processor)
a. cooling shroud