Users Guide

Sensors 293
Graph Information
The Graph Information page displays the graphs for the system power level
in Watts and power supplies in Amperes over a time period. The page auto
refreshes every minute.
NOTE: The data is obtained by the DRAC 5 every five minutes and is lost after a
DRAC reset, AC power cycle, or a firmware update.
NOTE: The graphs may display gaps either when the system is powered down or
when the BMC resets. This is because the power sensors are unavailable during
this period.
Power Consumption in Watts displays the time period over which the data
for power is collected. You can set the X-axis range to 1 hour, 1 day, or 1 week
from the drop-down menu available on this page. The time period is from the
current time set on the DRAC. The Y-axis displays the power consumed by
the system in Watts.
Power Consumption in Amperes displays the time period over which the data
for current is collected. You can set the X-axis range to 1 hour, 1 day, or 1
week from the drop-down menu available on this page. The time period is
from the current DRAC time. The Y-axis displays the current consumed by
the power supplies in Amperes. If there are more than one power supply units
on the system and if the readings are the same, the current graphs may
overlap each other.
Power Consumption Information
The Power Consumption Information page displays the power consumed by
the system in Watts and the average current consumed by each power supply
in Amperes.
This page also displays the status of the probes, probe name, power
consumed, the minimum and maximum thresholds at which warning and
failure alerts are generated, location of the power supply unit, and the average
current consumed by each power supply in Amperes.