Users Guide
274 Configuring Intelligent Platform Management Interface (IPMI)
• New line sequences
• Input new line sequences
For more information about these properties, see the IPMI 2.0
specification.
Using the IPMI Remote Access Serial Interface
In the IPMI serial interface, the following modes are available:
•
IPMI terminal mode
— Supports ASCII commands that are submitted
from a serial terminal. The command set has a limited number of
commands (including power control) and supports raw IPMI commands
that are entered as hexadecimal ASCII characters.
•
IPMI basic mode
— Supports a binary interface for program access, such
as the IPMI shell (IPMISH) that is included with the Baseboard
Management Utility (BMU).
To configure the IPMI mode using RACADM:
1
Disable the RAC serial interface.
At the command prompt, type:
racadm config -g cfgSerial -o
cfgSerialConsoleEnable 0
2
Enable the appropriate IPMI mode.
For example, at the command prompt, type:
racadm config -g cfgIpmiSerial -o
cfgIpmiSerialConnectionMode
<
0
or
1
>
See "DRAC 5 Property Database Group and Object Definitions" on page 345
for more information.