Users Guide

252 Using the DRAC 5 SM-CLP Command Line Interface
Property Names for Intrusion, Battery, Voltage, and Hardware
Performance Sensors
TotalOutputPower The total power output as shown
on the DRAC user interface
ElementName Name of the particular sensor.
OperationalStatus Current operational status of the
power supply unit.
HealthState The health status of the power
supply unit.
EnabledState Indicates if the sensor is enabled
or disabled
1=Enabled
Table 13-12. Supported Property Names for Intrusion, Battery, Voltage, and Hardware
Performance Sensors
Object Property Description
CIM_NumericSensor SystemCreation
ClassName
The name of the system creation class—
CIM_ComputerSystem)
SystemName The service tag of the system, which is a
unique identifier of a system that exists
in the enterprise environment
CreationClassN
ame
The creation class name —CIM_Sensor
DeviceID Unique ID for the sensor in the system
Intrusion1…n (for intrusion sensor)
Battery1…n (for battery sensor)
Voltage1…n (for voltage sensor)
Hardware performance sensor1…n (for
hardware performance sensor)
SensorType 1=Other
3=Voltage (for voltage sensor)
Table 13-11. Supported Property Names for Power Supply Sensors
(continued)