Users Guide

池管理
13-7 提供了使用 SM-CLP 在电池上执行操作的示例。
13-7.池管理操作
属性:
InstanceID = IPMI:BMC1 SEL Log
MaxNumberOfRecords = 512
CurrentNumberOfRecords = 5
Name = IPMI SEL
EnabledState = 2
OperationalState = 2
HealthState = 2
Caption = IPMI SEL
Description = IPMI SEL
ElementName = IPMI SEL
命令:
cd
show
help
exit
version
查看 SEL 记录
->show /system1/logs1/log1/record4
/system1/logs1/log1/record4
属性:
LogCreationClassName = CIM_RecordLog
CreationClassName = CIM_LogRecord
LogName = IPMI SEL
RecordID = 1
MessageTimeStamp = 20050620100512.000000
000
Description = FAN 7 RPM: fan sensor,
detected a failure
ElementName = IPMI SEL Record
命令:
cd
show
help
exit
version
清除 SEL
->delete /system1/logs1/log1/record*
所有记录成功删除
操作
查看电池状态
->show system1/batteries1/sensor1
/system1/batteries1/sensor1:
属性:
SystemCreationClassName = CIM_ComputerSystem
SystemName = F196P1S
CreationClassName = CIM_Sensor
DeviceID = BATTERY 1
SensorType = 1
PossibleStates = {"Good" "Bad" "Unknown"}
CurrentState = good
ElementName = System Board CMOS Battery
OtherSensorTypeDescription = CMOS battery sensor.
EnabledState = 1
Verb:
cd
exit
help