9. Verify the settings and connection by pinging the TFTP server.
RAC Recover> recover ping <TFTP server IP>
(If ping does not work, you may need to enter recover racreset
first).
10. Download and update the flash part.
RAC Recover> recover fwupdate -g -a <TFTP server IP>
11. RAC card will now update and reboot on completion.
#####################################################################
CHANGE IN DEFAULT CONFIGURATION SETTINGS
#####################################################################
For Firmware Version 1.50:
None
######################################################################
KNOWN ISSUES FOR DRAC 5
######################################################################
* In Firefox browser on Linux systems, sometimes the plug-ins for
virtual media and console redirection are shown as unsigned. This
is an issue with the Firefox browser and can be checked by
downloading the plugins and relogging in to the DRAC 5.
* When you use Internet Explorer version 6 SP2 or version 7 to log
into the DRAC 5 Web GUI and the client is on a private network but
without access to the Internet, you may experience a delay of up to
30 seconds. To work around this issue, do the following:
1. Disable the phishing filter.
"https://phishingfilter.microsoft.com/faq.aspx"
2. Disable CRL fetching:
a. Click “Tools”-> “Options”-> “Advanced” [tab]-> “Security.”
b. Clear “Check for publisher's certificate revocation.”
* Gemsafe Smart Cards GXPPro-R3.x STD PTS works only with
Classic Client Version 5.1.3 -003. This software is not freely
available and has to be requested from the Gemalto sales
representative or distributor while buying the card.
* When AC power is applied to the system but it is still powered down,
the date and time in the DRAC 5 will be Jan 1, 1970. When the system
is powered on, the DRAC 5 time is updated to the system time.
Henceforth, DRAC5 syncs up with the system time every hour. Once in
the operating system, if the system time is changed, then in order
to sync the DRAC 5 time with the system time immediately,
reboot the system.
* For Smart Card based authentication, currently, only Gemalto
cryptographic smart cards and compatible cryptographic smart card
service provider drivers are supported. Ensure that a