Users Guide

60 Advanced Configuration of the DRAC 5
Configuring Terminal Mode
1
Expand the
System
tree and click
Remote Access
.
2
Click the
Configuration
tab and then click
Serial
.
3
In the
Serial Configuration
page, click
Terminal Mode Settings
.
4
Configure the terminal mode settings.
See Table 4-9 for description of the terminal mode settings.
5
Click
Apply Changes
.
6
Click the appropriate
Terminal Mode Settings
page button to continue.
See Table 4-10 for description of the terminal mode settings page buttons.
Table 4-8. Serial Configuration Page Settings
Button Description
Print Print the Serial Configuration page.
Refresh Refresh the Serial Configuration page.
Apply Changes Apply the IPMI and RAC serial changes.
Terminal Mode Settings Opens the Terminal Mode Settings page.
Table 4-9. Terminal Mode Settings
Setting Description
Line Editing Enables or disables line editing.
Delete Control Select one of the following:
BMC outputs a <bksp><sp><bksp> character when
<bksp> or <del> is received
BMC outputs a <del> character when <bksp> or
<del> is received
Echo Control Enables or disables echo.
Handshaking Control Enables or disables handshaking.
New Line Sequence Select None, <CR-LF>, <NULL>, <CR>, <LF-CR>,
or <LF>.
Input New Line
Sequence
Select <CR> or <NULL>.