Configure IPMI Serial.
a
In the
Configuration
tab, click
Serial
.
b
In the
Serial Configuration
menu, change the IPMI serial connection
mode to the appropriate setting.
Under
IPMI Serial
, click the
Connection Mode Setting
drop-down
menu, select the appropriate mode.
c
Set the IPMI Serial baud rate.
Click the
Baud Rate
drop-down menu, select the appropriate baud
rate, and click
Apply Changes
.
d
Set the Channel Privilege Level Limit.
Click the
Channel Privilege Level Limit
drop-down menu, select
Administrator
,
Operator
, or
User
.
e
Click
Apply Changes
.
f
Ensure that the serial MUX is set correctly in the managed system’s
BIOS Setup program.
Restart your system.
During POST, press <F2> to enter the BIOS Setup program.
Navigate to
Serial Communication
.
•In the
Serial Connection
menu, ensure that
External Serial
Connector
is set to
Remote Access Device
.
Save and exit the BIOS Setup program.
Restart your system.
If IPMI serial is in terminal mode, you can configure the following
additional settings:
Delete control
Echo control
Line edit
New line sequences
Input new line sequences
For more information about these properties, see the IPMI 2.0
specification.