Users Guide
Using the DRAC 5 SM-CLP Command Line Interface 239
Property Names for Fan and Power Supply Redundancy Set Sensors
OtherSensorTyp
eDescription
If the sensortype property
contains a value of "1" (others),
this property gives additional
description about that sensor.
"Chassis intrusion sensor" (for
Intrusion sensor)
"CMOS battery sensor" (for
Battery sensor)
"Hardware performance sensor"
(for Hardware Performance)
EnabledState Indicates if the sensor is enabled
or disabled
1=Enabled (for all sensors)
Table 12-13. Supported Property Names for Fan and Power Supply Redundancy Set
Sensors
Object Property Description
InstanceID Instance number
RedundancyStatus The redundancy status.
TypeOfSet 3=Load balanced (for fan
redundancy)
4=Sparing (for Power Supply
redundancy)
MinNumberNeeded 0=Unknown
ElementName Name of the sensor
Table 12-12. Supported Property Names for Intrusion, Battery, Voltage, and Hardware
Performance Sensors (continued)
Object Property Description