54 Installing and Setting Up the DRAC 5
For example, to set the IPMI LAN channel privilege to 2 (User), type
the following command:
racadm config -g cfgIpmiLan -o
cfgIpmiLanPrivilegeLimit 2
b
Set the IPMI LAN channel encryption key, if required.
NOTE: The DRAC 5 IPMI supports the RMCP+ protocol. See the IPMI 2.0
specifications for more information.
At the command prompt, type the following command and press
<Enter>:
racadm config -g cfgIpmiLan -o
cfgIpmiEncryptionKey
<key>
where
<key>
is a 20-character encryption key in a valid hexadecimal
format.
3
Configure IPMI Serial over LAN (SOL).
At the command prompt, type the following command and press <Enter>:
racadm config -g cfgIpmiSol -o cfgIpmiSolEnable 1
a
Update the IPMI SOL minimum privilege level.
NOTICE: The IPMI SOL minimum privilege level determines the minimum
privilege required to activate IPMI SOL. For more information, see the IPMI 2.0
specification.
At the command prompt, type the following command and press
<Enter>:
racadm config -g cfgIpmiSol -o
cfgIpmiSolMinPrivilege
<level>
where
<level>
is one of the following:
2
(User)
3
(Operator)
4
(Administrator)