114 Configuring the DRAC 5 Using the Web User Interface
Table 4-28. IPMI Serial Settings
Setting Description
Connection Mode
Setting
Direct Connect Basic Mode - IPMI Serial Basic Mode
Direct Connect Terminal Mode - IPMI Serial Terminal
Mode
Baud Rate Sets the data speed rate. Select 9600 bps, 19.2 kbps,
57.6 kbps, or 115.2 kbps.
Flow Control
None — Hardware Flow Control Off
RTS/CTS — Hardware Flow Control On
Channel Privilege
Level Limit
Administrator
•Operator
•User
Table 4-29. RAC Serial Settings
Setting Description
Enabled Enables or disables the RAC serial console. Checked=
Enabled; Unchecked=Disabled
Maximum Sessions The maximum number of simultaneous sessions allowed
for this system.
Timeout The maximum number of seconds of line idle time before
the line is disconnected. The range is 60 to 1920 seconds.
Default is 300 seconds. Use 0 seconds to disable the
Timeout feature.
Redirect Enabled Enables or disables Console Redirection. Checked=
Enabled; Unchecked=Disabled
Baud Rate The data speed on the external serial port. Values are 9600
bps, 28.8 kbps, 57.6 kbps, and 115.2 kbps. Default is
57.6 kbps.
Escape Key Specifies the <Esc> key. The default are the ^\
characters.