Users Guide

76 Managing and Recovering a Remote System
Configuring Alerts by Severity
1
Use the
Severity Configuration
section to select which events, according
to their severity, will cause an SNMP alert to be sent to the IP address you
typed in
Configuring Alert Properties
.
2
Select the severity of the sensor for which you want an SNMP alert
generated.
3
Use Table 4-8 to decide which events you want to cause an SNMP alert.
Table 4-8. Severity Options
Option Description
Informational The DRAC 4 sends an alert if the corresponding event listed
under Alert Description occurs with a severity of Informational
(lowest severity).
Warning The DRAC 4 sends an alert if the corresponding event listed
under Alert Description occurs with a severity of Warning
(medium severity).
Severe The DRAC 4 sends an alert if the corresponding event listed
under Alert Description occurs with a severity of Severe
(highest severity).
Alert Description Lists the following events monitored by the DRAC 4. An alert
(specified as either informational, warning, or severe) is sent
when the event is triggered at the level of severity you selected
in the check boxes to the left.
NOTE: For information about how to manage events, see the
Server Administrator User's Guide.
Select All
— Monitors all of the sensors available on the
system.
System Temperature Sensors
— Monitors the temperature
sensors on the system.
System Voltage Sensors
— Monitors the voltage sensors on the
system.
System Fan Sensors
— Monitors the system fan speed (RPM).
System Miscellaneous Sensors
— Monitors other available
system sensors such as chassis intrusion.