Users Guide

DRAC 4 Overview 17
Hardware Specifications
Power Requirements
Table 1-1 lists the power requirements for the DRAC 4.
Connectors
NOTE: The DRAC 4 hardware installation instructions are located in the Installing a
Remote Access Card document or the Installation and Troubleshooting Guide
included with your system. Ensure that you connect the management cable and the
local video monitor (if present) to the DRAC 4/P in PCI slot 4.
The DRAC 4 provides a dedicated 10/100 Mbps RJ-45 NIC and a connector
for mounting the card to the system board. The DRAC 4/P also provides a
video connector, and a 30-pin Management Connector.
DRAC 4 Ports
Table 1-2 identifies the ports used by the DRAC 4. This information is
required when opening firewalls for remote access to a DRAC 4.
Table 1-1. DRAC 4 Power Requirements
System Power
1.2 A on +3.3 V AUX (maximum)
550 mA on +3.3 V main (maximum)
0 mA on+5V main (maximum)
Table 1-2. DRAC 4 Port Numbers
DRAC 4 Port Number Used For
Ports on DRAC 4 listening for connection (server):
22
Secure Shell (configurable)
23
Telnet (configurable)
80
HTTP (configurable)
161
SNMP Agent (not configurable)
443
HTTPS (configurable)