276 DRAC 4 Property Database Group and Object Definitions
Alert Filter Properties
The alert filter property group ID is cfgUserAdmin. The object IDs are shown
in Table B-6.
Alert Test Commands
You can test alerts using test commands. The racadm command has
subcommands that test the different types of alert interfaces. These object ID
sets cause the firmware to execute the subcommand with the option that
indicates the test alert type to test. The test message is preset in properties for
each test alert type. The types of alerts are email and trap.
The following subsection describes the command interfaces and the
operation of the subcommand for each option.
Table B-6. Alert Filter Property Group and Object IDs
GroupID Object ID Object Default
Value
cfgUserAdmin cfgUserAdminPageEmailEnable FALSE
cfgUserAdmin cfgUserAdminPageEmailAddress ""
cfgUserAdmin cfgUserAdminPageEmailCustomMsg ""
cfgUserAdmin cfgUserAdminAlertFilterRacEventMask 0x777777
cfgUserAdmin cfgUserAdminAlertFilterSysEventMask 0x777777
cfgRemoteHosts cfgRhostsSmtpServerIpAddr 0.0.0.0
cfgOobSnmp cfgOobSnmpTrapsEnable TRUE
cfgTraps cfgTrapsDestIpAddr 0.0.0.0
cfgTraps cfgTrapsEnable FALSE
cfgTraps cfgTrapsSnmpCommunity ""
cfgTraps cfgTrapsFilterRacEventMask 0x777777