Release Notes
file:///T|/htdocs/SOFTWARE/smdrac3/dracmc/1.3/EN/readme/DRACMC_readme.txt[10/29/2012 3:56:12 PM]
#######################################################################
NEW FEATURES IN THIS RELEASE (FIRMWARE VERSION 1.3)
#######################################################################
* Support for Dell PowerEdge 1955 server module
* Support for remote RACADM utility version 5.0.0
* Support for backing up and restoring configuration objects
* Support for user-configurable system names
* Support for SUSE Linux Enterprise Server (version 9)
* Enhanced power budget implementation using redundancy policy
selections
######################################################################
CORRECTED ISSUES IN THIS RELEASE (FIRMWARE VERSION 1.3)
######################################################################
* DRAC/MC web interface may time out when a firewall is enabled on the
client. This has been reported with the integrated Windows firewall
introduced with Windows XP SP1 and SP2.(38783/64357)
* TFTP update timer value does not allow firmware update with Spanning
Tree Protocol enabled. (42780)
* Due to the default "CRLF" settings in Windows-based telnet clients,
the text mode console redirection feature may not function properly
on server modules running the Linux operating system.
This issue can also occur when connecting to I/O modules using
console redirection.
Use the "connect -L" option from DRAC/MC CLI to filter the linefeed
character. (46543)
Alternatively, to fix this issue, configure the "CRLF" option
on the telnet client to only send CR characters with the Windows
telnet command "unset crlf." (146185)
* All server modules may power off if one defective power supply is
present in the chassis. (67592)
######################################################################
KNOWN ISSUES FOR DRAC/MC VERSION 1.3
######################################################################
The following subsections list the known issues regarding the DRAC/MC
version 1.3 implementation and operation:
* If a DRAC/MC with version 1.0 firmware is configured in a redundant
DRAC/MC configuration during a firmware update, the update may