Release Notes
ID Issue Description/Workaround
20426 Replication traffic that is configured to go
through an assigned bond may still run
through the default bond (bond0).
If you want to run replication traffic through another bond
interface, contact Technical Support to update the route.
18837 Manual modifications made to the Rapid NFS
rdnfs.cfg file are not preserved between plug-
in updates.
Manually modify the rdnfs.cfg again after upgrading the
plug-in.
17294 A NetVault Backup data copy or duplication
will stop if the DR Series system goes into
maintenance mode as it moves into a read-
only condition when this occurs.
Restart the datacopy operation after the DR Series system
enters the operational mode.
17206 Advanced networking allows you to change
the IP of an interface that is part of a
replication link.
Understand your current configuration before adding new
advanced networking configuration so that you do not
impact the current system configuration.
16280 When you try to get replication statistics, the
system displays the Software error:
Use of uninitialized value in
division (/) at helper.pl line
3548 error.
This is due to the replication target not being in an
operational state. Correct the replication target and refresh
or use the CLI. The information is available by using the
command line. We will correct this error in a future release.
9433 The dedicated hot spare is not automatically
configured after replacing the hot spare drive
in slot 0.
If the hot spare is replaced, run maintenance by using the
--make_standby command. Contact Dell Technical
Support for this action.
Known Issues and Resolutions
The following table lists known issues and related resolutions addressed in this DR Series system release.
ID Issue Resolution
23879 Backup spanning across multiple tapes fail
when 10 GB tape is used for Microsoft DPM.
Recommendations for backups spanning multiple
tapes are documented in the DR Series best
practices guide for Microsoft DPM available for your
specific DR Series system at dell.com/support/home.
23641 Cannot join into the domain by adding a DR
Series system to multiple OUs.
In the authenticate command type the format as
follows:--ou topLevelOU/
middleLevelOU/LowerLevelOU/
TargetOU
This format for adding OUs is now documented in
the latest
Dell DR Series System CLI Guide
.
20870 RPC replication errors may be seen during
replication from source DR Series system to
target DR Series system.
The primary and secondary replication target should
have the same MTU setting. Replication proceeds
once the MTU is set to the same as the replica
target. This recommendation has been added to the
section, “Managing Replication Operations,” in the
latest
Dell DR Series System Administrator’s Guide
.
7