Administrator Guide
Table Of Contents
- Dell DR Series System Administrator Guide
- DR Series システムの概要
- Understanding the DR Series System
- About the DR Series System
- ドライブ容量と使用可能な物理容量
- Data Storage Terminology and Concepts
- Supported File System Protocols
- OpenStorage Technology (OST): DR Series System
- Rapid Data Storage (RDS): DR Series System
- DR Series System and Data Operations
- Supported Software and Hardware
- DR Series — Expansion Shelf Cabling
- DR Series システム拡張シェルフの追加
- Setting Up the DR Series System
- Interacting With the DR Series System
- Connections for Initializing a DR Series System
- DR Series システムの初期化
- RACADM を使用した iDRAC6/iDRAC7 へのアクセス
- Logging in Using a Web Interface
- Dashboard(ダッシュボード)ページとオプション
- Storage(ストレージ)ページとオプション
- About the Schedules Page and Options
- About the System Configuration Page and Options
- Support(サポート)ページとオプション
- Configuring the DR Series System Settings
- Managing DR Series Storage Operations
- DR Series システムの監視
- DR Series システムのサポートオプションの使用
- OST の設定と使用
- OST の理解
- OpenStorage Technology(OST)API
- OST ガイドライン
- OST Terminology
- Supported OST Software and Components
- OST Required Configurations
- ベストプラクティス:OST と DR Series システム
- クライアント側の最適化の設定
- Configuring an LSU
- Installing the Dell OST Plug-In
- NetBackup を使用した DR Series システム情報の設定
- Backing Up Data From a DR Series System (NetBackup)
- Using Backup Exec With a DR Series System (Windows)
- OST Plug-In and Supported Versions
- Installation Prerequisites for the OST Plug-In for Backup Exec
- Backup Exec GUI を使用した DR Series システムの設定
- Backup Exec を使用した DR Series システム上でのバックアップの作成
- Optimizing Duplication Between DR Series Systems Using Backup Exec
- Restoring Data from a DR Series System Using Backup Exec
- Understanding the OST CLI Commands
- Understanding OST Plug-In Diagnostic Logs
- Linux ユーティリティを使用した診断の収集
- メディアサーバー情報の収集に関するガイドライン
- Configuring and Using Rapid Data Storage
- RDS Overview
- RDS Guidelines
- Best Practices: RDS and the DR Series System
- Setting Client-Side Optimization
- Adding RDS Devices in NVBU
- Removing RDS Devices From NVBU
- Backing Up Data on the RDS Container Using NVBU
- Replicating Data to an RDS Container Using NVBU
- Restoring Data From a DR Series System Using NVBU
- Supported DR Series System CLI Commands for RDS
- Troubleshooting and Maintenance
- Supported Ports in a DR Series System
- 困ったときは

メモ: After you have reset the login password to its default and logged in to the DR Series system, Dell
recommends for security reasons that you create a new unique login password.
4. In Service Tag, type the Service Tag associated with your system.
メモ: If you are unsure of the Service Tag associated with your DR Series system, it can be found on the
Support page (click Support in the navigation panel to display the Support Information pane, which displays
the Service Tag).
5. In Administrator Email enter the email address of the administrator of this system.
The Administrator Email that you enter must match the administrator email address configured in the DR Series
system. If you have set security questions, the security questions are displayed.
6. Enter the answers to the configured security questions in Answer 1 and Answer 2.
7. Click Send Now.
An email with a unique code, used to reset the password, is sent only to the configured administrator email
address. The code is valid for only 15 minutes. The password rest code expires after 15 minutes and cannot be
used. You must repeat the password reset procedure to regenerate the code again.
DR Series システムのシャットダウン
必要に応じて、System Configuration(システム設定)ページの Shutdown(シャットダウン)を選択すること
で、DR Series システムをシャットダウンできます。ただし、システムのシャットダウンを試みる前に、シス
テム動作に対するこのアクションの意味を十分に理解しておくことが必要です。
注意: シャットダウンにより、DR Series システムソフトウェアがインストールされているアプライアン
スの電源がオフになります。いったん電源オフにすると、物理的な場所で再び電源をオンにするか、DR
Series システムへの iDRAC 接続を使用する必要があります。
DR Series システムをシャットダウンするには、次の手順を実行します。
1. ナビゲーションパネルで、System Configuration(システム設定)を選択します。
System Configuration(システム設定)ページが表示されます。
2. System Configuration(システム設定)ページのオプションバーで Shutdown(シャットダウン)をクリッ
クします。
Shutdown confirmation(シャットダウンの確認)ダイアログが表示されます。
3. Shutdown System(システムのシャットダウン)をクリックしてシステムのシャットダウンを続行します
(または、Cancel(キャンセル)をクリックして System Configuration(システム設定)ページに戻りま
す)。
DR Series システムの再起動
System Configuration(システム設定)ページの Reboot(再起動)オプションを選択することにより、必要に応
じて
DR Series システムを再起動できます。システムを再起動するには、次の手順を実行します。
1. ナビゲーションパネルで、System Configuration(システム設定)を選択します。
System Configuration(システム設定)ページが表示されます。
2. System Configuration(システム設定)ページのオプションバーで Reboot(再起動)をクリックします。
Reboot System(システムの再起動)確認ダイアログが表示されます。
3. Reboot System(システムの再起動)をクリックしてシステムの再起動を続行します(または Cancel(キ
ャンセル)をクリックして System Configuration(システム設定)ページに戻ります)。