Administrator Guide
Table Of Contents
- Dell DR Series System Administrator Guide
- DR Series システムの概要
- Understanding the DR Series System
- About the DR Series System
- ドライブ容量と使用可能な物理容量
- Data Storage Terminology and Concepts
- Supported File System Protocols
- OpenStorage Technology (OST): DR Series System
- Rapid Data Storage (RDS): DR Series System
- DR Series System and Data Operations
- Supported Software and Hardware
- DR Series — Expansion Shelf Cabling
- DR Series システム拡張シェルフの追加
- Setting Up the DR Series System
- Interacting With the DR Series System
- Connections for Initializing a DR Series System
- DR Series システムの初期化
- RACADM を使用した iDRAC6/iDRAC7 へのアクセス
- Logging in Using a Web Interface
- Dashboard(ダッシュボード)ページとオプション
- Storage(ストレージ)ページとオプション
- About the Schedules Page and Options
- About the System Configuration Page and Options
- Support(サポート)ページとオプション
- Configuring the DR Series System Settings
- Managing DR Series Storage Operations
- DR Series システムの監視
- DR Series システムのサポートオプションの使用
- OST の設定と使用
- OST の理解
- OpenStorage Technology(OST)API
- OST ガイドライン
- OST Terminology
- Supported OST Software and Components
- OST Required Configurations
- ベストプラクティス:OST と DR Series システム
- クライアント側の最適化の設定
- Configuring an LSU
- Installing the Dell OST Plug-In
- NetBackup を使用した DR Series システム情報の設定
- Backing Up Data From a DR Series System (NetBackup)
- Using Backup Exec With a DR Series System (Windows)
- OST Plug-In and Supported Versions
- Installation Prerequisites for the OST Plug-In for Backup Exec
- Backup Exec GUI を使用した DR Series システムの設定
- Backup Exec を使用した DR Series システム上でのバックアップの作成
- Optimizing Duplication Between DR Series Systems Using Backup Exec
- Restoring Data from a DR Series System Using Backup Exec
- Understanding the OST CLI Commands
- Understanding OST Plug-In Diagnostic Logs
- Linux ユーティリティを使用した診断の収集
- メディアサーバー情報の収集に関するガイドライン
- Configuring and Using Rapid Data Storage
- RDS Overview
- RDS Guidelines
- Best Practices: RDS and the DR Series System
- Setting Client-Side Optimization
- Adding RDS Devices in NVBU
- Removing RDS Devices From NVBU
- Backing Up Data on the RDS Container Using NVBU
- Replicating Data to an RDS Container Using NVBU
- Restoring Data From a DR Series System Using NVBU
- Supported DR Series System CLI Commands for RDS
- Troubleshooting and Maintenance
- Supported Ports in a DR Series System
- 困ったときは

During replication, the system processes data storage requests from a specified source to a specified destination (also
known as a target) that acts as a replica of the original source data.
メモ: Starting with Release 2.0, the DR Series system software includes version checking that limits replication
only between other DR Series systems that run the same system software release version (DR Series systems
running Release 2.0.x software can only replicate with other DR Series systems that run the same release system
software). For example, Release 2.0.x systems will not be able to replicate with Release 2.1 or Release 3.0 systems,
but can replicate with systems running Release 2.0.0.1 or 2.0.0.2.
メモ: It is important to distinguish the difference between data that has been processed by backup and data that
has been processed by replication, since backup saves a copy of data that remains unchanged for a long period of
time.
Targets with replica data are read-only, and are updated with new or unique data during scheduled or manual
replications. The DR Series system can be considered to act as a form of the storage replication where the backed up
and deduplicated data is replicated in real-time or via a scheduled window. In a replication relationship between two DR
Series systems, this means that a relationship exists between a pair of systems, one acting as the source and the other
as a target in the replication pair (for example, with acme-west and acme-east). When this type of replication
relationship exists between distinct containers on two distinct DR Series systems, it can be considered bidirectional in
the sense that:
• West1 container on the acme-west source system can replicate data to a separate East1 container on the
acme-east target system.
• The East2 container on the target acme-east system can also replicate data back to the West2 container on the
source acme-west system.
This form of replication involves separate containers on two distinct DR Series systems. Target containers in replication
must always act as read-only, while source containers can act as read-write. Unlike NFS and CIFS containers, OST and
RDS container replication is handled by the two supported Data Management Applications (DMAs) on media servers.
For more information on OST, see Understanding OST. For more information on RDS, see Configuring and Using Rapid
Data Storage.
メモ: OST and RDS containers are categorized as Rapid Data Access (RDA) containers in DR Series systems.
This release of the DR Series system supports the 32:1 replication of data, whereby up to 32 source DR Series systems
can write data to different individual containers on a single, target DR Series system. This supports the use case where
branch or regional offices can each write their own data to a separate, distinct container on a main corporate DR Series
system.
メモ: Be aware that the storage capacity of the target DR Series system is directly affected by the number of
source systems writing to its containers, and by the amount being written by each of the source systems.
If the source and target systems in a replication pair reside in different Active Directory (AD) domains, then the data that
resides on the target DR Series system may not be accessible. When AD is used for authentication for DR Series
systems, the AD information is saved with the file. This can serve to restrict user access to the data based on the type of
AD permissions that are in place.
メモ: This same authentication information is replicated to the target DR Series system when you have replication
configured. To prevent domain access issues, ensure that both the target and source systems reside in the same
Active Directory domain.
Reverse Replication: The concept of reverse replication is not supported on DR Series systems. This is because replica
containers are always in a R-O (read-only) mode on the DR Series system, thus making write operations a non-
supported operation. Under very specific conditions, it might be possible for replica containers to support a type of write
operation whose sole function is to restore data from an archival target. For example, data could be replicated back to
the remote site where a data management application (DMA), also known as backup software, is connected to allow
this data to be restored directly.
15