Administrator Guide

System Event Message Description/Meaning or Action
Internal Error. Datastore <
variable
> length mismatch
<
variable
>.
Maintenance-based issue with the DR Series system. Check
status using Maintenance mode or DR Series system CLI
commands. Contact Dell Support as needed.
Data volume capacity threshold reached. Informational message. No user intervention is required.
Out of space. Rollback of updates on object <
variable
>
failed. Restarting file server.
Maintenance-based issue with the DR Series system. Check
status using Maintenance mode or DR Series system CLI
commands. Contact Dell Support as needed.
Failure reading from data volume. Maintenance-based issue with the DR Series system. Check
status using Maintenance mode or DR Series system CLI
commands. Contact Dell Support as needed.
Failure writing to data volume. Maintenance-based issue with the DR Series system. Check
status using Maintenance mode or DR Series system CLI
commands. Contact Dell Support as needed.
Checksum verification on metadata failed. Contact Dell Support for assistance or repair the filesystem.
For repairs, see
About The DR Series Maintenance Mode.
Internal Error. Optimization engine log replay failed. Contact Dell Support for assistance or repair the filesystem.
For repairs, see About The DR Series Maintenance Mode.
Decompression of datastore failed <
variable
>. Contact Dell Support for assistance or intervention.
Internal Error. Failed to clean active datastore
<
variable
>.
Contact Dell Support for assistance or intervention.
Internal Error. Negative reference on datastore
<
variable
>. Record type: <
variable
>. Count: <
variable
>.
Contact Dell Support for assistance or repair the filesystem.
For repairs, see the topic, “About the DR Series Maintenance
Mode.”
Internal Error. Data store <
variable
> contains negative
stream reference count. Record type: <
variable
>.
Count: <
variable
>.
Informational message. No user intervention is required.
Internal Error. Data store <
variable
> total reference
count reached threshold. Record type: <
variable
>.
Count: <
variable
>.
Informational message. No user intervention is required.
Data store[%s] stream(s) marked bad. A chunk of data on the system failed consistency check. An
attempt will be made to correct this chunk of data.
Internal Error. Entering Maintenance mode due to
failure in processing logs.
Contact Dell Support for assistance or intervention.
Internal Error. Failed to acquire optimizer pipeline.
Error: <
variable
>.
Contact Dell Support for intervention or assistance.
Internal Error. Failed to create optimizer event. Type:
<
variable
>, Error: <
variable
>.
Contact Dell Support for intervention or assistance.
Internal Error. Task execution in fiber <
variable
> timed
out after <
variable
> milliseconds (ms). Restarting file
server.
Filesystem restarted. Collect diagnostics log file bundle, and
upload diagnostics log file bundle to Dell Support.
173