30 Setting up the Dell DR Series System with IBM Tivoli Storage Manager
3.2 Configuring DR Series system VTL for Windows and Linux TSM
servers
Note: Refer to the following instructions for viewing the tape devices and IDs, which you will need to
configure the DR Series system VTL.
For Windows: To see the Tape Library device IDs, use the command “tsmdlst.” For example:
cd C:\program files\Tivoli\TSM\Server\Tsmdiag
.\tsmdlst.exe
For Linux: For discovering the tape devices and their IDs, refer to Appendix C later in this document.
3.2.1 Configuring the DR Series system VTL for Windows
3.2.1.1 Define library
# define library TSM-iscsi libtype=scsi shared=yes autolabel=yes
(TSM-iscsi is user defined name for the library)
3.2.1.2 Define library path
# define path WIN-8B1A4SA50SR TSM-iscsi srct=server autodetect=yes destt=library
device=lb0.1.0.3
Where:
• WIN-8B1A4SA50SR = TSM server hostname
• Device = Device ID for medium changer listed by “tsmdlst” command.
3.2.1.3 Define drive
# define drive TSM-iscsi drive01 online=yes
Where:
• TSM-iscsi = Library name defined in earlier command
• Drive01 = User defined drive name
3.2.1.4 Define drive path
# define path WIN-8B1A4SA50SR drive01 srct=server destt=drive library=TSM-iscsi
device=mt0.2.0.3 online=yes
3.2.1.5 Audit the library
# audit library TSM-iscsi checklabel=barcode