White Papers
DR Series Best Practice Guide
33
Scenario 4: Multiple appliance replication
Jose has one DR4100 appliance located at his Seattle site and two DR4100s located at his Lansing site.
He wants to replicate data from his Seattle site (Seattle1) to his Lansing site (Lansing1). He would also
like to replicate data backed up at Lansing1 to another site, Lansing2.
Jose will need to do the following to accomplish his goals:
Create bonds on the appropriate interfaces on all three appliances.
Add replication to the designated interfaces.
Establish network routes between the DR appliances.
The appliances will be configured as follows:
Seattle1: 2x 10GB interfaces in bond0 and 2x 1GB interfaces in bond1
Lannsing1: 2x 10GB interfaces in bond0 and 2x 1GB interfaces in bond1
Lansing2: 2x 10GB interfaces in bond0
Scenario 4 topology