Release Notes
domain. If the issue persists, close the AppAssure Appliance
Configuration Wizard, delete the configuration file below and
restart the wizard. C:\Program Files\Dell\PowerVault\Appliances
\DL\FTBU\FTBU.dat If the issue still persist, contact Dell
support further assistance.
Workaround/
Solution
Reboot your appliance to join the domain.
Status of Appliance tab indicator is yellow if the RASR
USB drive is not created
Description It is recommended to create the RASR USB drive when the AppAssure Appliance
Configuration Wizard is running. If the RASR USB drive is not created, then the
Rapid Appliance Self Recovery status on the health page turns yellow. This in turn
causes the Appliance tab indicator to turn yellow.
Appliance tab does not have any content
Description When you click the Appliance tab, the content inside the table is not displayed. The
following error message is displayed instead: The following error occurred
during the previous installation attempt. This typically happens when
the AppAssure core is updated in RUU, and the AppAssure core is open in a
browser.
Workaround/
Solution
Clear browser cache. Go to Internet Options in IE, click General → Browsing
history → delete browsing history and press Delete. Restart the browser.
"Collecting..." message remains on the screen while
collecting DL Appliance logs
Description "Collecting...” message remains on the screen while trying to collect logs in
AppAssure Core through Tools → Diagnostics →View Logs.
Workaround/
Solution
Press F5 to refresh the browser.
Appliance tab loses functionality
Description Occasionally, you may see that Appliance tab does not respond. The rotating
progress button is stuck.
Workaround/
Solution
1. Restart Internet Information Service Manager.
2. Restart the services in the given order:
a. Windows Management Instrumentation
b. SRM Web Service
20