Practices Guide

LC Integration Best Practices Specification
57
the NIC. Approximate time for completion on a 12G system is 20-30 minutes depending on the
system configuration.
Applies to: LC2+
Prerequisites for script:
Intel NIC Mezz card
Set desired script variables by editing script
NOTES:
Make sure Mezz NIC is enabled
If not enabled, enable it and find NIC FQDD, reboot
Enable ConnectFirstFCoETarget
Check if ConnectFirstFCoETarget is enabled, if not enable it
Configure FCoE, reboot
Move FCoE to the top of the HD Boot List
Script: FCoEboot-12g-IntelMezz.win
A) The Lifecycle Controller remote service must be in a “ready” state before executing any other
WSMAN commands. GetRemoteServicesAPIStatus():
1. System should be power off
2. Clear all unfinished jobs
3. Clear all pending data
B) Check NIC is enabled
1. GetBIOSEnumerations(): ENUMERATE the DCIM_BIOSEnumeration class to collect
information about the system. See section 2.2 for a definition of ENUMERATE.
2. Ensure AttributeName of Slot2 is enabled
If it is not enabled, enable it as shown below
SetBIOSAttributes()
AttributeName= Slot2 AttributeValue=Enabled
AttributeName=BootMode AttributeValue=Bios
CreateBIOSConfigJob()
ScheduledStartTime=TIME_NOW RebootJobType=1
Poll jobstatus for Completed: GET the InstanceID of from 2).