User's Manual
256 iDRAC6 and CMC Property Database Group and Object Descriptions
FILE LOCATION: 
C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACADM\Source\rac
DELL CONFIDENTIAL – PRELIMINARY 3/26/13 - FOR PROOF ONLY
cfgServerPowerSupplyType
cfgIPv6LanNetworking
This group is used to configure the IPv6 over LAN networking capabilities.
  NOTE: Use this object with the config or getconfig subcommands.
NOTE: To use this object property for CMC, you must have Chassis Configuration 
Administrator privilege.
NOTE: Use the -m option to apply this setting to iDRAC.
The following sections provides information about the objects in the 
cfgIPv6LanNetworking group.
cfgIPv6Enable (Read/Write)
cfgIPv6Address
  NOTE: This object is applicable only for CMC.
Description Displays whether the power supply is AC or DC. 
Legal Values A string of up to 32 characters.
Default 0
Description Enables or disables iDRAC6 or CMC IPv6 stack.
Legal Values 1 (TRUE)
0 (FALSE)
Default 0
Description Assigns a static IPv6 address to the CMC. This property is used 
only if cfgIPv6AutoConfig is set to 0 (false).
Legal Values A string representing a valid IPv6 address. For example, 
2001:DB8:1234:5678:9ABC:DE11:C00C:BEEF
Default
::