230 iDRAC6 and CMC Property Database Group and Object Descriptions
FILE LOCATION: 
C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACADM\Source\rac
DELL CONFIDENTIAL – PRELIMINARY 3/26/13 - FOR PROOF ONLY
cfgChassisInMaxPowerCapacity (Read Only)
Indicates the total chassis power budget (in watts) available for chassis 
operation.
cfgChassisInRedundancyReserve (Read Only)
Indicates the amount of redundant power (in watts) in reserve that can be 
utilized in the event of an AC grid or PSU failure. This value is 0 if the 
Redundancy Policy is set to 0 (no redundancy).
cfgChassisInPowerServerAllocation (Read Only)
Indicates (in watts) the cumulative power allocated to servers. There is no 
default as this parameter is very specific to the particular customer 
configuration.
cfgChassisInfrastructureInPowerAllocation (Read Only)
Indicates the estimated cumulative DC output power consumption (in 
watts), determined from a field replaceable unit (FRU) on the hardware 
modules in the chassis.
cfgChassisTotalInPowerAvailable (Read Only)
Indicates the amount of power (in watts) available for use by the chassis.
cfgChassisStandbyInPowerCapacity (Read Only)
Indicates the amount of power (in watts) available for powering up any 
hardware modules that are either added to the chassis or powered up (if they 
are already present in the chassis). 
cfgChassisPowerClear (Write Only)
To reset cfgChassisMinPower and cfgChassisMaxPowerCapacity, set this 
object to 1.
cfgChassisPowerClearTimestamp (Read Only)
Time stamp when cfgChassisMinPower and cfgChassisMaxPowerCapacity 
were reset.