setflexaddr
  NOTE: To use this subcommand, you must have Chassis Configuration 
Administrator privilege.
NOTE: If the fabric type is determined to be Infiniband, the operation is canceled 
and the command returns an error. If the FlexAddress feature is not activated, the 
command returns an error.
NOTE: The server must be powered off to change the slot state. All servers must be 
powered off to change the fabric state. The MAC/WWN addresses must be 
managed locally (not by an external console) to use this command.
Synopsis
racadm setflexaddr [-i <slot#> <state>] 
[-f <fabricName> <state>]
<slot#> = 1 to 16
<fabricName> = A, B, C
<state> = 0 or 1
where 0 is disable and 1 is enable.
Table 2-32 describes the setflexaddr subcommand options.
Subcommand Description
setflexaddr Enables/disables FlexAddress on a particular slot/fabric. 
Table 2-32. setflexaddr Subcommand Options
Option Description
-i <slot#> <state> Enables/disables FlexAddress for the specified slot.