Owners Manual
LED Indicators
Front panel
• One two-digit LCD indicator for Unit ID, error code, and unit
location identifier
• One two-color LED indicator for power status
• One single-color LED indicator for module fault status
(enclosure as a whole)
• One single-color LED indicator for logical fault status (drive,
HBA, RAID controller, and so on)
• One single-color LED indicator for drawer 1 fault status
• One single-color LED indicator for drawer 2 fault status
Drawer
• One single-color LED indicator for sideplane card and power
status
• One single-color LED indicator for drawer fault status
• One single-color LED indicator for logical fault status
• One single-color LED indicator for cable fault status
• Six single-color LED indicators for data transfer status
Disk Drive In Carrier (DDIC) One single-color LED for drive fault status
6 Gb SAS IO module 14 one-color LED status indicators, four each for the three SAS
ports and two for the module status
Cooling module
• One single-color LED indicator for module status
• One single-color LED indicator for battery fault status (not
currently used)
• One single-color LED indicator for fan fault status
Power Supply Unit (PSU)
• One single-color LED indicator for PSU fault status
• One single-color LED indicator for AC power fault status
• One single-color LED indicator for power status
Power Supplies
AC power supply (per power supply)
Wattage 2.8 kW
Voltage 200–240 VAC (8.6 A–4.3 A)
Heat dissipation 191-147 W
Maximum inrush current Under typical line conditions and over the entire system ambient
operating range, the inrush current may reach 55 A per power
supply for 10 ms or less
Available Hard Drive Power (Per Slot)
Supported hard drive power consumption (continuous)
Up to 1.16 A at +5 V,
Up to 1.6 A at +12 V
IO Card Power (Per Slot)
Maximum power consumed by IO Card 11 W at +12 V
Maximum available power 100 W at +12 V
Maximum available power 1 W at +5 V (standby)
Physical
Height 22.23 cm (8.75 inches)
Width 48.26 cm (19 inches)
12 Technical Specifications