Deployment Guide
Figure 6. Single-Appliance Fibre Channel 10GbE Cluster Conguration With an SC4020 Storage System
1.
Client network 2. Internal network
3. Fibre Channel SAN switch 4. SC4020 with 10Gb FC ports
5. Client network connections 6. FS8600 internal network connections
7. Storage Center fault domain 1 connections 8. Storage Center fault domain 2 connections
Example of Multi-Appliance FC 10GbE Cluster Conguration
The following example shows the best-practices conguration for multi-appliance Fibre Channel 10GbE clusters.
• Client network – Each FS8600 controller has multiple connections to each stacked Ethernet switch.
• Internal network – Each FS8600 controller has multiple connections to the stacked internal network Ethernet switches.
• Fibre Channel SAN – Each FS8600 controller has a connection to each FC fabric (Storage Center fault domain).
NOTE: To simplify the diagram, only one FS8600 appliance is shown. Additional appliances in the cluster must be
connected to the same client network, internal network, and FC SAN fabric.
20
Install and Connect the FS8600 Hardware