Reference Guide
Table Of Contents
- Dell Command | PowerShell Provider Version 2.4 Reference Guide
- Introduction to Dell Command | PowerShell Provider 2.4
- Attributes supported in Dell Command | PowerShell Provider 2.4
- AdvancedBootOptions
- AdvancedConfigurations
- BatteryInformation
- BIOSSetupAdvancedMode
- BootSequence
- Connection
- Integrated Devices
- IntelSoftwareGuardExtensions
- Keyboard
- Manageability
- Maintenance
- MemoryInformation
- MiscellaneousDevices
- Passwords
- Performance
- POSTBehavior
- PowerManagement
- PreEnabled
- ProcessorInformation
- SecureBoot
- Security
- StealthModeControl
- SupportAssistSystemResolution
- SystemConfiguration
- SystemInformation
- SystemLogs
- ThermalConfiguration
- TPMSecurity
- USBConfiguration
- Video
- VirtualizationSupport
- Wireless
- Error reporting in Dell Command | PowerShell Provider 2.4
- Accessing documents from the Dell EMC support site
Table 25. SystemConfiguration (continued)
Attribute Name Description
● Enabled—If enabled, when the BIOS boots next time, the first PXE-capable device is
inserted as the first device in the boot sequence. Enabling this value causes this
operation on the next boot only, and does not cause a change in the defined boot
sequence of the system. The BIOS chooses the first PXE-capable device as the
onboard network controller of the system, if present and enabled, or the first
bootable network device found in the standard PCI search order of the system,
whichever comes first.
● Disabled—If disabled, the boot override feature is disabled and the system boot
sequence is in effect.
FrontPowerButton Enables or disables the front power button. The following are the possible values:
● Enabled
● Disabled
Hdd1FanEnable Enables or disables the automatic fan controller, an error check of a fan. If a fan is
detected, this function is automatically enabled. Disabling the fan requires physical
removal of the HDD fan. The following are the possible values:
● Enabled
● Disabled
Hdd2FanEnable Enables or disables the automatic fan controller, an error check of a fan. If a fan is
detected, this function is automatically enabled. Disabling the fan requires physical
removal of the HDD2 fan. The following are the possible values:
● Enabled
● Disabled
Hdd3FanEnable Enables or disables the automatic fan controller, an error check of a fan. If a fan is
detected, this function is automatically enabled. Disabling the fan requires physical
removal of the HDD3 fan. The following are the possible values:
● Enabled
● Disabled
IgnitionSwitchEnable Enables or disables the external ignition pin. Disabled by default. The following are the
possible values:
● Enabled
● Disabled
IgnitionSwitchOnDelay The delay is displayed in seconds when the power button event is passed to the OS to
initiate a boot of the system. Possible values are from (0—21600). By default the value is
5s.
IgnitionSwitchOffDelay The delay is displayed in seconds untill the power button event is passed to the OS for
shutting down the system. Possible values are from (0—21600). By default the value is
5s.
IgnitionSwitchDebounceCycle De-Bounce Ignition Power Switch cycle time is displayed in milli-seconds. Possible values
are from (50—5000). By default the value is 50ms.
IntegratedAudio Enables or disables the integrated audio controller. The following are the possible values:
● Enabled
● Disabled
● Auto
IntegratedSas Enables or disables the integrated Serial Attached SCSI (SAS) controller.
NOTE: This option affects the SAS RAID controller Only. This controller operates the
connectors on the motherboard that are marked SASA and SASB.
The following are the possible values:
● Enabled
● Disabled
InternalSpeaker Enables or disables the built-in speaker. The following are the possible values:
38 Attributes supported in Dell Command | PowerShell Provider 2.4