Reference Guide
Table Of Contents
- Dell Command | PowerShell Provider Version 2.2 Reference Guide
- Introduction to Dell Command | PowerShell Provider 2.2
- Attributes supported in Dell Command | PowerShell Provider 2.2
- AdvancedBootOptions
- AdvancedConfigurations
- BatteryInformation
- BIOSSetupAdvancedMode
- BootSequence
- IntelSoftwareGuardExtensions
- Manageability
- Maintenance
- MemoryInformation
- MiscellaneousDevices
- Performance
- POSTBehavior
- PowerManagement
- PreEnabled
- ProcessorInformation
- SecureBoot
- Security
- StealthModeControl
- SupportAssistSystemResolution
- SystemConfiguration
- SystemInformation
- SystemLogs
- ThermalConfiguration
- TPMSecurity
- USBConfiguration
- Video
- VirtualizationSupport
- Wireless
- Error reporting in Dell Command | PowerShell Provider 2.2
- Accessing documents from the Dell EMC support site
Table 26. USBConfiguration (continued)
Attribute Name Description
● BIOSAssistEnum
● NativeEnum
DisableDockDevicesexceptvide
o
Enables or disables all devices such as serial, audio, LAN, and USB ports in the docking
station.
Possible values:
● Enabled
● Disabled
NOTE: This option works only when UsbPortsExternal is enabled.
FrontUSB3.0Ports
Enables or disables the front USB 3.0 ports.
Possible values:
● Enabled
● Disabled
RearUSB3.0Ports
Enables or disables the rear USB 3.0 ports.
Possible values:
● Enabled
● Disabled
ThunderboltBoot
Enables or disables booting from the Thunderbolt device.
Possible values:
● Enabled
● Disabled
ThunderboltPorts
Enables or disables the thunderbolt ports controller in the system.
Possible values:
● Enabled
● Disabled
Thunderbolt
Enables or disables the thunderbolt controller in the system.
Possible values:
● Enabled
● Disabled
ThunderboltPreboot
Enables OROMs and pre-boot UEFI drivers provided by Thunderbolt devices or PCIe
devices.
Possible values:
● Enabled
● Disabled
ThunderboltSecLvl
Configures the thunderbolt security level.
Possible values:
● NoSec — Disables the thunderbolt security.
● UserAuth — Allows minimum user notification. Connection manager requests
connection approval from the host software, based on the unique ID of the connecting
device, auto approval might or might not be given.
● SecConn — Allows one-time saved key device. Connection manager requests
connection approval from the host software; approval is given only if the host
challenge to device is acceptable.
● DpUsbOnly — Allows to connect only display port.
Attributes supported in Dell Command | PowerShell Provider 2.2 53