Users Guide

{
Category = "PowerManagement"
BlockDefinition="1"
AdvancedBatteryChargeConfiguration = "Tuesday"
BeginningOfDay = "10:30"
WorkPeriod = "15:45"
}
PowerManagement PowerManagementSettingsSunday #resource name
{
Category = "PowerManagement"
BlockDefinition="2"
AdvancedBatteryChargeConfiguration = "Sunday"
BeginningOfDay = "13:30"
WorkPeriod = "15:45"
}
}
}
Configuring PeakShiftDayConfiguration in category
Powermanagement
Configuration PowerManagementConfigurationPeak
{
Import-DscResource -ModuleName DellBIOSProvider
Node localhost {
PowerManagement PowerManagementSettingsSaturday #resource name
{
Category = "PowerManagement"
BlockDefinition="1"
PeakShiftDayConfiguration = "Saturday"
StartTime = "10:30"
EndTime = "12:30"
ChargeStartTime = "13:30"
}
PowerManagement PowerManagementSettingsWednesday #resource name
{
Category = "PowerManagement"
BlockDefinition="2"
PeakShiftDayConfiguration = "Wednesday"
StartTime = "12:30"
EndTime = "15:30"
ChargeStartTime = "16:45"
}
}
}
Enforcing simple configuration for category POSTBehavior when
BIOS password is set
NOTE:
When the BIOS password is set on the client system, the password must be provided through the 'Password'
property.
Configuration POSTBehaviorConfiguration
{
Import-DscResource -ModuleName DellBIOSProvider
Node clientMachine01 {
POSTBehavior POSTBehaviorSettings #resource name
{
Category = "POSTBehavior"
Keypad = "EnabledByNumlock"
Password = “biospassword”
}
26