Reference Guide
Attribute Name Description
• Keep — Does not clear the system event log on the next boot.
• Clear — Clears the system event log on the next boot.
PowerLogClear
Prevents or allows the power event log to be cleared on the next boot.
Possible values:
• Keep — Does not clear the power event log on the next boot.
• Clear — Clears the power event log on the next boot.
ThermalLogClear
Prevents or allows the thermal event log to be cleared on the next boot.
Possible values:
• Keep — Does not clear the thermal event log on the next boot.
• Clear — Clears the thermal event log on the next boot.
ThermalConfiguration
Table 25. ThermalConfiguration
Attribute Name Description
FanSpdAutoLvlonCpuZone
Sets the speed of the fan on CPU zone
Possible values:
• 0 to 100
FanSpdAutoLvlonPsuZone
Sets the speed of the fan on PSU zone
Possible values:
• 0 to 100
FanSpdAutoLvlonCpuMemZone
Sets the speed of the fan on CPU memory zone
Possible values:
• 0 to 100
FanSpdAutoLvlonPcieZone
Sets the speed of the fan on PCIe zone
Possible values:
• 0 to 100
FanSpdAutoLvlonFlexBayZone
Sets the speed of the fan on Flex Bay zone
Possible values:
• 0 to 100
FanSpdAutoLvlonUpperPcieZone
Sets the speed of the fan on Upper PCIe zone
Possible values:
• 0 to 100
TPMSecurity
Table 26. TPMSecurity
Attribute Name Description
PpibypassSedBlockSidCommand
When there is no drive ownership and the PpibypassSedBlockSidCommand is enabled, the BIOS
requires user input while sending the Block SID authentication command to SED drives. When
52 Attributes supported in Dell Command | PowerShell Provider 2.3