Release Notes

Fixes
Following issues were xed during this release:
Issue: The PSPath displayed is incorrect.
Description: While running the following gi .\SystemInformation | fl * command, PSPath is displayed as DellBIOSProvider
\DellSmbiosProv::DellBIOS:\SystemInformation.
Resolution: Change DellBIOS to DellSMBIOS.
This issue has been addressed in the current release.
Issue: Error message ‘could not nd the path’ was displayed due to ‘/’ during auto completion of the category name in the systems running
Windows 8 and later
This issue has been xed now. User should be able to navigate to the location after using auto completion for the category name.
Issue: Success message was part of console and needed to be handled separately.
This issue has been xed now. Success message is now displayed as part of the verbose switch during set operation.
Issue: Unable to set KeyboardIllumination to ‘100’ percent using Dell Command | PowerShell Provider.
This issue has been xed now. KeyboardIllumination attribute can be set as ‘Bright’ (100%)..
Issue: Dell Command | PowerShell Provider showed MemoryTechnology attribute as ‘TBD’ on some platforms with the latest memory
technology such as DDR4, LPDDR, LPDDR2, LPDDR3, or LPDDR4.
This issue has been xed now. MemoryTechnology attribute is now shown on the platforms with the latest technology such as DDR4,
LPDDR,..etc.
Issue: HTCapable attribute displays ‘No’ even if supported in few systems.
This issue has been xed now. HTCapable attribute displays the accurate information.
8