Users Guide
– Charging starts based on the battery percent defined in CustomChargeStart.
– Charging ends based on the battery percent defined in CustomChargeStop.
• Set-Item -Path DellSmbios:\PowerManagement\CustomChargeStart “65” command can be used to start
battery charging at 65%.
• Set-Item -Path DellSmbios:\PowerManagement\CustomChargeStop “95” command can be used to stop
battery charging at 95%.
• Possible values for the CustomChargeStart attribute ranges from 50 to 95 percent and for the CustomChargeStop percent
ranges from 55 to 100 percent.
Using the PeakShiftDayConfiguration feature
This feature allows you to configure the PeakShiftDayConfiguration option in the PowerManagement category. Peak Shift
configuration minimizes AC power consumption during the peak power usage period of the day. During the Peak Shift period, AC
power will not be consumed, and the system runs on battery if the battery charge is more than the set battery threshold value.
After the Peak Shift period, the system runs on AC power, if available, without charging the battery. The system functions normally
using AC power, and recharges the battery after the specified Charge Start Time.
PeakShiftCfg — Enables or disables the peak shift configuration.
• Enabled — Enables the peak shift configuration on specific days for a specific period specified using Peak Shift Start Time,
Peak Shift End Time, and Peak Shift Charge Start Time.
• Disabled — Disables the peak shift configuration feature.
If enabled, configure the following:
NOTE: The configuration applies to all batteries: Primary, Slice, and Module Bay.
• StartTime — Specifies the time when system starts consuming battery power. The system continues consuming the battery
power until either the peakshift battery threshold is reached, or peakshift end time is reached.
• EndTime — Specifies the time when system stops consuming battery power and starts consuming AC power, if available.
However, the system does not charge battery.
• ChargeStartTime — Specifies the time when the system starts charging the battery while consuming AC power, if available.
NOTE: Peak Shift Start Time must be less than or equal to Peak Shift End Time, and Peak Shift End Time must be less
than or equal to Peak Shift Charge Start Time.
Example: To retrieve the PeakShiftDayConfiguration current settings. The StartTime, EndTime, and ChargeStartTime are displayed
for all days.
Get-Item -Path DellSmbios:\PowerManagement\PeakShiftDayConfiguration
Example: To set the PeakShift StartTime, EndTime, and ChargeStartTime for Sunday.
Set-Item -Path DellSmbios:\PowerManagement\PeakShiftDayConfiguration Sunday -StartTime
"12:45" -EndTime "14:30" -ChargeStartTime "16:15"
Example: To change StartTime value for Monday. EndTime and ChargeStartTime values remain unchanged for Monday.
Set-Item -Path DellSmbios:\PowerManagement\PeakShiftDayConfiguration Monday -StartTime
"09:00"
Using the Keyboard Backlight Color feature
This feature allows you to configure the supported colors for the keyboard backlight on rugged systems. There are six available
colors: four predefined colors (white, red, green, blue), and two user configurable colors (custom1 and custom2). You can configure
custom1 and custom2 colors using KeyboardBacklightCustom1Color and KeyboardBacklightCustom2Color attributes.
KeyboardBacklightEnabledColors
Possible values: White, Red, Green, Blue, Custom1, Custom2, and NoColor.
20