Users Guide
• Enabled — Enables AdvBatteryChargeCfg.
• Disabled — Disables AdvBatteryChargeCfg. If disabled, battery charging mode is based on Primary Battery Charge
Configuration, Battery Slice Charge Configuration, Primary Battery Custom Charge Start, and Primary Battery Custom Charge
End.
To configure the AdvanceBatteryCharge time period, provide the following values:
• BeginningOfDay — Configures the AdvanceBatteryCharge start time in 24 hours format. The value of hour must be in the
range 0–23 and minute must be 0, 15, 30, or 45.
• WorkPeriod — Configures the duration of charging.
For example, to set AdvancedBatteryChargeConfiguration from 7:15 a.m. to 2:30 p.m., set BeginningOfDay as 7:15 and set
WorkPeriod as 7:15.
NOTE: To set 12 a.m., provide the hour value as 00.
Example: To enable AdvBatteryChargeCfg.
Command: Set-Item AdvBatteryChargeCfg "Enabled"
Example: To set the charge time from 11 a.m. to 2 p.m. on Saturdays.
Command: Set-Item AdvancedBatteryChargeConfiguration –value Saturday –Beginningofday
“11:00” –Workperiod “3:00”
Example: To set BeginningOfDay value only. Workperiod value for Monday remains unchanged.
Set-Item AdvancedBatteryChargeConfiguration -value Monday -Beginningofday "09:00"
Using the PrimaryBattChargeCfg feature
This feature allows you to configure the primary battery charging option in the PowerManagement category. The selected charging
mode applies to all batteries installed in the system. Select one of the following modes:
• Auto — Battery settings are adaptively optimized based on your typical battery usage pattern.
• Standard — Charges the battery at a standard rate.
• Express — Charges the battery faster using the express charging algorithm, Dell's fast charging technology.
• PrimACUse — Charges the battery while plugged-in, preferred for the users who operate their system while plugged in to an
external power source.
• Custom — The battery charging starts and stops based on the settings specified in Primary Battery Custom Charge Start and
Primary Battery Custom Charge End.
– CustomChargeStart — Sets the percent value ranging from 50 to 95 at which the custom battery charging should start.
– CustomChargeStop — Sets the percent value ranging from 55 to 100 at which the custom battery charging should stop.
NOTE: CustomChargeStart percent must be less than CustomChargeStop percent, and the minimum difference
between the two can be no less than 5 percent.
Example: To retrieve the current mode of the PrimaryBattChargeCfg attribute.
Get-ChildItem -Path DellSmbios:\PowerManagement\PrimaryBattChargeCfg
If the status retrieved as Custom, then to know the percent when charging starts and ends, retrieve CustomChargeStart and
CustomChargeStop attributes.
Example: To set the battery charging mode as standard.
Set-Item -Path DellSmbios:\PowerManagement\PrimaryBattChargeCfg "Standard"
Example: To set the battery charge mode as custom and then to specify the start time and duration when the battery should be
charged.
Set-Item -Path DellSmbios:\PowerManagement\PrimaryBattChargeCfg "Custom"
• Sets the PrimaryBattChargeCfg attribute to charge battery based on user settings specified in CustomChargeStart and
CustomChargeStop attributes. If the value 'Custom' is chosen,
19