Release Notes
Table Of Contents
Issue: While stopping the data manager service, an error message might be displayed saying the process cannot be stopped.
But the service will be stopped.
Issue: For LSI controllers, status or event may not be generated when the Battery Backup Unit (BBU) is degraded.
Resolution: The BBU degraded status can be viewed in the application log for event (Id #161 of category type: Warning)
generated by source MR_MONITOR.
Issue: After upgrading from Windows OS, enumerating WMI classes may not display appropriate results.
Resolution: Reinstall Dell Command | Monitor to the newer build or repair the build from control panel.
Issue: Error message might be displayed in Application Log of event viewer while restarting the system or service.
Issue: Hyper-v does not work
Description: Hyper-v doesn’t work if Dell Command | Monitor is installed for the first time on clean installation of Windows 10.
Resoultion: Rebuild Hyper V WMI repository by executing the command:
MOFCOMP <SYSTEMROOT>\System32\WindowsVirtualization.V2.mof
Issue: DCIM_Docked class displays value Unknown for ElementName property.
Issue: HAPI driver shipped with Dell Command | Monitor version 10.1 and 10.0 complies with Windows Hardware Quality Labs
(WHQL) for Windows 10. A security message is displayed while installing Dell Command | Monitor on any other Windows
operating systems.
Resolution: Upgrade to latest Dell Command | Monitor.
Issue:After the setup password has been set in DINO-XPS-Win7 or any other platform, then those platforms does not allow you
to set the system password.
Issue: Windows failed to initiate DSM Data Manager service on a local computer.
Resolution: Visual C++ Re-distributable for Visual Studio 2015 must be installed.
Limitations
Not applicable.
Installation Instructions
For information and procedure for installing Dell Command | Monitor, see the Dell Command | Monitor - Installation Guide,
available at dell.com/dellclientcommandsuitemanual.
Installation Prerequisites
.NET Framework 4.6.1 or later is installed.
For windows 7 and 8.1, Visual C++ Redistributable for Visual Studio 2015 must be installed.
NOTE: Dell Command | Monitor 10.2.1 supports Windows only operating system.
For systems running Microsoft Windows
Before installing Dell Command | Monitor, ensure that:
● You have administrative rights on the client system. This means that you must be authenticated on the client system as a
user who is a member of the administrator's group, typically the administrator.
● The target system is a Dell system with SMBIOS version 2.3 or later. Otherwise, the Dell Command | Monitor installer exits
without installing. You can get the SMBIOS version using the following command in PowerShell command line interface:
get-ciminstance win32_bios | select SMBIOSMajorVersion, SMBIOSMinorVersion
● Systems must be compatible with WMI-ACPI compliant BIOS.
7