Table 32. Sensor (continued)
Property Description
and OperationalStatus properties. Further, the first value of OperationalStatus
should contain the primary status for the element. When instrumented, Status
(because it is single-valued) should also provide the primary status of the element.
Possible values are:
0 = Unknown
1 = Other
2 = OK
3 = Degraded
4 = StressedIndicates that the element is functioning, but needs attention.
Examples of Stressed states are overload, overheated, and so on.
5 = Predictive FailureIndicates that an element is functioning nominally but
predicting a failure in the near future.
6 = Error
7 = Non-Recoverable Error
8 = Starting
9 = Stopping
10 = StoppedImplies a clean and orderly stop.
11 = In ServiceDescribes an element being configured, maintained, cleaned, or
otherwise administered.
12 = No ContactIndicates that the monitoring system has knowledge of this
element, but has never been able to establish communications with it.
13 = Lost CommunicationIndicates that the ManagedSystem Element is known
to exist and has been contacted successfully in the past, but is currently
unreachable.
14 = AbortedImplies an abrupt stop where the state and configuration of the
element may need to be updated.
15 = DormantIndicates that the element is inactive or quiesced.
16 = Supporting Entity in ErrorIndicates that this element may be OK but that
another element, on which it is dependent, is in error. An example is a network
service or endpoint that cannot function due to lower-layer networking problems.
17 = CompletedIndicates that the element has completed its operation. This
value should be combined with either OK, Error, or Degraded so that a client can
tell if the complete operation Completed with OK (passed), Completed with Error
(failed), or Completed with Degraded (the operation finished, but it did not
complete OK or did not report an error).
18 = Power ModeIndicates that the element has additional power model
information contained in the Associated PowerManagementService association.
.. = DMTF Reserved
0x8000.. = Vendor Reserved
PossibleStates
Enumerates the string outputs of the Sensor. For example, a Switch Sensor may
output the states On, or Off. Another implementation of the Switch may output the
states Open, and Close. Another example is a NumericSensor supporting thresholds.
This Sensor can report the states like Normal, Upper Fatal, Lower Non-Critical,
and so on. A NumericSensor that does not publish readings and thresholds, but
stores this data internally, can still report its states.
PrimaryStatus
Provides a high level status value, intended to align with Red-Yellow-Green type
representation of status. It should be used in conjunction with DetailedStatus to
provide high level and detailed health status of the ManagedElement and its
subcomponents.
Possible values are:
0 = UnknownIndicates the implementation is in general capable of returning
this property, but is unable to do so at this time.
1 = OKIndicates the ManagedElement is functioning normally.
132 Dell Command | Monitor 10.4 classes and properties