Table 31. NumericSensor (continued)
Property Description Supported
Operating
System(s)
0 = UnknownThe implementation cannot report on HealthState at this time.
5 = OKThe element is fully functional and is operating within normal
operational parameters and without error.
10 = Degraded/WarningThe element is in working order and all functionality is
provided. However, the element is not working to the best of its abilities. For
example, the element may not be operating at optimal performance or it may be
reporting recoverable errors.
15 = Minor failureAll functionality is available but some may be degraded.
20 = Major failureThe element is failing. It is possible that some or all of the
functionality of this component is degraded or not working.
25 = Critical failureThe element is non-functional and recovery may not be
possible.
30 = Non-recoverable errorThe element has completely failed, and recovery
is not possible. All functionality provided by this element has been lost.
.. = DMTF Reserved
DMTF has reserved the unused portion of the continuum for additional
HealthStates in the future.
LowerThresholdCriti
cal
The Sensor's threshold values specify the ranges (min and max values) for
determining whether the Sensor is operating under Normal, NonCritical or Critical
conditions. The CurrentState is Critical once the CurrentReading is below
LowerThresholdCritical.
Windows, Linux
LowerThresholdNon
Critical
The Sensor's threshold values specify the ranges (min and max values) for
determining whether the Sensor is operating under Normal, NonCritical, Critical
conditions. If Current Reading is between LowerThresholdNonCritical and Upper
ThresholdNonCritical, then the Sensor is reporting a normal value. If
CurrentReading is between LowerThresholdNonCritical and LowerThresholdCritical,
then the CurrentState is NonCritical.
Example for Set command: wmic /namespace:\\root\dcim\sysman path
dcim_numericsensor Where ElementName like '%Temperature Sensor:%' set
LowerThresholdNonCritical = 30. This sets the all temperature probes (lower
threshold non critical) in the system to 30 degree Celsius.
Windows, Linux
NormalMax
NormalMax provides guidance for the user as to the normal maximum range for the
NumericSensor.
Linux
NormalMin
NormalMin provides guidance for the user as to the normal minimum range for the
NumericSensor.
Linux
OperationalStatus
Indicates the current statuses of the element. Various operational statuses are
defined. Many of the enumeration's values are self-explanatory.
Possible values are:
0 = Unknown
1 = Other
2 = OK
3 = Degraded
4 = StressedIndicates that the element is functioning, but needs attention.
Examples of Stressed states are overload, overheated, and so on.
5 = Predictive FailureIndicates that an element is functioning nominally but
predicting a failure in the near future.
6 = Error
7 = Non-Recoverable Error
8 = Starting
Windows, Linux