Release Notes
Table Of Contents
● Energy star logo
Issue: dsm_sa_datamgr32 service stops responding while installing chipset driver.
Description: This issue occurs only when Dell Command | Monitor is installed on some platforms before installing the chipset
driver.
Issue: SecureEraseSupported and SecureEraseEnabled parameters in HDDInfo displays ‘No’ even if enabled from BIOS setup
screen.
This issue is addressed in the upcoming BIOS versions.
Issue: dsm_sa_datamgr32 service stops responding while installing chipset driver.
Issue: Class DCIM_PhysicalDiskView enumerates only IDE disk drives for Intel controller.
Issue: The value of Link technology property in DCIM_EthernetPort class appears empty.
Description: If the value of any attributes is not in English, then that attributes field may appear blank. For example,
DCIM_EthernetPort_LinkTechnology. Dell Command | Monitor is not localized and is an English language application; however,
Dell Command | Monitor can be installed on other operating system language versions such as French, German, Spanish,
Japanese, Korean, Simplified Chinese, and Traditional Chinese of supported Windows operating systems.
Issue: Dell Command | Monitor allows enabling Secure Boot when Legacy Option ROM is enabled and boot mode is UEFI;
however, there is no negative impact due to this on the BIOS.
Issue: If the fan is not working as indicated by Health Status and OperationalStatus attributes, then the attributes Current
Status is blank.
Issue: The Non-Critical threshold levels for voltage and current cannot be negative values.
Issue: Setting the Non-Critical threshold levels for fans is not supported. For the attributes SettableThreshold, the Non-Critical
value can be set to Settable.
Issue: For temperature probe, the Upper Critical Threshold level should be greater than 0.
Issue: Digital signatures are missing for some third-party files.
Issue: Setting Lower Non-Critical Threshold attributes may not be supported although SupportedThreshold attributes show that
it is supported.
Issue: If the values of Upper Non-Critical Threshold for NumericSensor class are close to reading or status values, then an event
might be generated although the same might not be shown in the class attributes.
Issue: Lower Threshold alerts are not generated; however, they can be monitored using the Current State attributes in
NumericSensor class.
Issue: Degraded status and alert for physical disk is not supported with LSI controllers.
Issue: In LogEntry the element name for alerts is displayed as Alert Log Entry <Alert ID>.
Issue: While stopping the data manager service, an error message might be displayed saying the process cannot be stopped. But
the service will be stopped.
Issue: For LSI controllers, status or event may not be generated when the Battery Backup Unit (BBU) is degraded.
Resolution: The BBU degraded status can be viewed in the application log for event (Id number 161 of category type: Warning)
generated by source MR_MONITOR.
Issue: After upgrading from Windows operating system, enumerating WMI classes may not display appropriate results.
Resolution: Reinstall Dell Command | Monitor to the newer build or repair the build from control panel.
Issue: Error message might be displayed in Application Log of event viewer while restarting the system or service.
Issue: Hyper-V does not work.
Description: Hyper-V does not work if Dell Command | Monitor is installed for the first time on clean installation of Windows 10.
Resolution: Rebuild Hyper-V WMI repository by running the command:
MOFCOMP <SYSTEMROOT>\System32\WindowsVirtualization.V2.mof
Issue: DCIM_Docked class displays value Unknown for ElementName property.
Issue: HAPI driver that is shipped with Dell Command | Monitor version 10.1 and 10.0 complies with Windows Hardware Quality
Labs (WHQL) for Windows 10. A security message is displayed while installing Dell Command | Monitor on any other Windows
operating systems.
Resolution: Upgrade to latest Dell Command | Monitor.
20